Test Equipment Specifications
Test Equipment Home --> OTDR --> Anritsu

 

ModelWavelengths [nm]Min.Pulse WidthMax Pulse WidthDistance Range Min.Distance Range Max.Distance ResolutionDynamic Range
MW9076C1310, 1550, 162510 nsec1 msec1 km400 km1 m ± 3 X measurement distance42 dB
MW9076B11310, 155010 nsec1 msec1 km400 km1 m ± 3 X measurement distance41 dB
MW9076B1310, 155010 nsec1 msec1 km400 km1 m ± 3 X measurement distance45 dB
MW90601310, 155010 nsec1 msec10 km100 km3 m34 dB
MW9076D11310, 1450, 1550, 162510 nsec1 msec1 km400 km0.1 m ± 3 X measurement distance34 dB
MW9060A1310, 155010 nsec1 msec10 km250 km10 cm to 50 m34 dB
MW9076J85010 nsec1 msec1 km100 km1 m ± 3 X measurement distance45 dB
MW9076K850, 130010 nsec1 msec1 km100 km1 m ± 3 X measurement distance45 dB
MW9077A1155010 nsec1 msec5 km400 km1 m ± 3 measurement distance X 1E-5 ± sampling resolution?
MW9077A131010 nsec1 msec5 km400 km1 m ± 3 measurement distance X 1E-5 ± sampling resolution?

 